We provide OEM process for valve mounting plate so many years .
Hydraulic valve block, that is, in the metal material on the installation hole according to the installation specifications of various hydraulic valves. Generally used in the school is a tube board, connected with a variety of pipes. But the industrial ,engineering hydraulic valves are plate , plug type of the more, these valves are connected by the hydraulic valve block. It has the advantages of compact structure and small structure.
The failure of the valve block mainly shows the large coordination gap between holes and rods, dynamic seal wear, wear of the console shoulder, cavitation, etc. There are the following three forms summarized:
(1) Performance degradation: approximately 15% of the failure;
(2) Performance decline: accounting for about 70% of the failure, divided into corrosion and mechanical wear, mechanical wear can be subdivided into wear, aging, adhesion damage;
(3) Accident: for about 15% of the failure.
The two main reasons for valve block failure are:
(1) The cleanliness of the oil is not enough;
(2) The system enters the air